Dismantling of 2 steam generators NPP Obrigheim, Germany

Description

Within demolition of the Obrigheim Nuclear Power plant, which had begun end of 2017, Hebetec Engineering was commissioned with the removal of steam generators.

The steam generators were lifted in a vertical position. A rotation into horizontal position was required for the loading onto SPMTs.

By applying equipment of Hebetec Engineering, it was possible to execute this rotation in the open room. Job Report

Facts

Weight of steam generators 160 t
Lowering height 15 m

Handling equipment

Strand jack H-40 4 pcs
Strand jack HA-10 4 pcs
Strand jack HA-40 6 pcs
Strand jack HA-140 2 pcs

 

Contact